IW-200 Infant Radiant Warmer

 

  • Microprocessor based servo controlled temperature system.
  • The microprocessor-controlled unit allows for
    three settings: pre-warm, manual or automatic.
  • Alarm functions for safety includes:
    Power failure.
    Temperature deviation.
    Temperature sensor probe failure.
    Over temperature.
  • Aluminum based structure for durability and rust free.
  • APGAR timer to record therapy time.
  • Convenient X-ray cassette, board, board under infant bed
  • Heater head can be adjusted + 90º horizontally.
  • Tilt angle of infant bed is adjustable.
  • Transparent protector folded.
  • Convenient X-ray cassette, board, board under infant bed.
  • Alarms are audible and visual.
  • A second thermal cut-out function for more safety.
  • Skin temperature sensor failure protect function avoid over temperature.
  • Skin temperature sensor fall protect function avoid over temperature
  • Temperature deviation can be amended in front panel directly
  • Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long.
  • RS-232 connector.

 

Click here to download IW-200 brochure

IW-400 Infant Radiant Warmer

  • Microprocessor based servo controlled temperature system.
  • The microprocessor-controlled unit allows for
    three settings: pre-warm, manual or automatic.
  • Alarm functions for safety includes:
    - Power failure.
    - Temperature deviation.
    - Temperature sensor failure.
    - Over temperature.
  • Aluminum based structure for durability and rust free.
  • APGAR timer to record therapy time.
  •  Convenient X-ray cassette under infant bed.
  • Heater head can be adjusted + 90º horizontally.
  • Tilt angle of infant bed is adjustable.
  • Observe light angle is adjustable.
  • Transparent protector folded.
  • Adopts anti-explosion micro crystal quartz infrared
    radiation tube for its radiation source, the heating is quick and life-span is long.
  • Alarms are audible and visual.
  • A second thermal cut-out function for more safety.
  • Skin temperature sensor failure protect function avoid over temperature.
  • Temperature deviation can be amended in front
    panel directly.

 

Click here to download IW-400 brochure

 



IW-1000 Infant Warmer


  • Microprocessor based servo controlled temperature system.
  • The microprocessor-controlled unit allows for three settings: pre-warm, manual, or automatic.
  • Alarm functions for safety includes:
    Power failure.
    Temperature deviation.
    Temperature sensor failure.
    Over temperature.
  • Aluminum based structure for durability and rust free.
  • APGAR timer to record therapy time.
  • Convenient X-ray cassette under infant bed.
  • Heater head can be adjusted + 90º horizontally.
  • Tilt angle of infant bed is adjustable.
  • Observe light angle is adjustable.
  • Transparent protector folded.
  • Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long.
  • Alarms are audible and visual.
  • A second thermal cut-off function for more safety.
  • Skin temperature sensor failure protect function avoid over temperature. temperature deviation can be amended in front panel directly.
  • Low pressure aspirator, oxygen supply system and LED phototherapy unit.

Click here to download IW-1000 brochure
 

IW-1100 Infant Warmer

 

  • Microprocessor based servo controlled temperature system.
  • The microprocessor-controlled unit allows for three settings: pre-warm, manual, or automatic.
  • Alarm functions for safety includes
    Power failure.
    Temperature deviation.
    Temperature sensor failure.
    Over temperature.
  • Aluminum based structure for durability and rust free.
  • APGAR timer to record therapy time.
  • Convenient X-ray cassette under infant bed.
  • Heater head can be adjusted + 90º horizontally.
  • Tilt angle of infant bed is adjustable.
  • Observe light angle is adjustable.
  • Transparent protector folded.
  • Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long.
  • Alarms are audible and visual.
  • A second thermal cut-off function for more safety.
  • Skin temperature sensor failure protect function avoid over temperature.
  • Temperature deviation can be amended in front panel directly.
  • Low pressure aspirator, oxygen supply system and LED phototherapy unit.
  • Electric height adjusted suit for operation.

Click here to download IW-1100 brochure


IW-2000 Infant Radiant Warmer


  • Three modes of control: manual, skin temperature, and mattress temperature.
  • Alloyed bracket.
  • Microprocessor based servo controlled temperature system.
  • Aluminum based structure for durability and rust free
  • Control panel displayed by VFD.
  • Digital skin temperature sensor, the data is exact and stabilized.
  • High sensitivity and untouched detector to inspect mattress temperature.
  • Alarm functions for safety includes:
    Power failure.
    Temperature deviation.
    Temperature probe failure.
    Over temperature.
  • APGAR timer to record therapy time.
  • Observe light angle can be adjusted + 90º, and the brightness is also adjusted.
  • Heater head can be adjusted + 90º horizontally.
  • Electric infant bed tilt angle is + 10º, transparent protector folded.
  • Convenient X-ray cassette under infant bed.
  • Electric height adjusted: suitable for operations.
  • Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long.
  • Alarms are audible and visual.
  • A second thermal cut-off function for more safety.
  • Skin temperature sensor failure protect function to avoid over temperature.

 

Click here to download IW-2000 brochure


 




RS 1000 Resuscitator

  • Reliably provide oxygen with content of 100%.
  • Accurately regulate and maintain a constant and uniform PIP (Peak Inspiratory Pressure).
  • Accurately regulate and maintain a constant and uniform PEEP (Positive End Expiratory Pressure).
  • The maximum pressure is controllable and adjustable.
  • Replace the temporary respiration support.
  • User friendly and portable.
  • Simple to operate, can be operated by only one hand.
RS 1000

 